PPD113B01-10-150000 3BHE023784R1023 specialized low-to-medium voltage Power Protection & Detection Module


PPD113B01-10-150000 (with 3BHE023784R1023 as its exclusive order number) is a specialized low-to-medium voltage Power Protection & Detection Module developed by ABB. It is tailored for entry-level to mid-range power electronic systems, focusing on cost-effective real-time fault detection, key parameter monitoring, and coordinated protection with ABB’s low-voltage control units (e.g., PPC380AE series). As a "safety guardian" for small-to-mid-power equipment (such as low-voltage drives, auxiliary converters, and small renewable energy inverters), it balances protection precision, ease of integration, and economic efficiency. The detailed information is as follows:

1. Basic Product Overview

CategoryDetails
ManufacturerABB (a global leader in power and automation technologies, adhering to international safety standards such as IEC 61800-5-2 (power drive systems – safety requirements) and IEC 60255 (relays and protection devices), trusted in light industry, building automation, and small-scale renewable energy sectors)
Product TypeLow-to-Medium Voltage Power Protection & Detection Module (dedicated to overcurrent/overvoltage/undervoltage detection, temperature monitoring, and fault signal transmission for small-to-mid-power electronic systems)
Model & Order NumberProduct Model: PPD113B01-10-150000
Order Number: 3BHE023784R1023 (unique identifier for procurement, inventory tracking, after-sales service, and compatibility verification with ABB’s low-voltage product ecosystem)
Package TypeCompact industrial panel-mounted enclosure (plastic-metal hybrid housing with basic anti-corrosion and dust-proof performance (IP20); integrated terminal blocks for signal input/output and power supply; front-panel LED indicators for core status (power on, normal operation, fault alert))
WeightApproximately 0.6–1.0 kg (lightweight and compact, easy to install in space-constrained cabinets; accessory kits include mounting screws, wiring guides, and a quick-configuration manual)
Key CompatibilityOptimized for ABB’s low-to-medium voltage entry-level products, including ACS580 series low-voltage drives (1.1kW–250kW), small solar inverters (10kW–50kW), and auxiliary power converters. It communicates seamlessly with ABB’s PPC380AE/PPC322BE series control units via simplified digital interfaces, enabling coordinated protection and control.

2. Key Electrical & Hardware Specifications

2.1 Power Supply Requirements

  • Input Voltage: Single 24VDC ±10% (for internal detection circuits and logic control; optional external redundant power input via auxiliary terminals for critical applications like medical equipment auxiliaries).
  • Power Consumption: Typical 5W (normal monitoring state), maximum 10W (fault detection and signal transmission state).
  • Isolation Performance:
    • Between power input terminals and signal terminals: ≥2000V AC (1 minute, IEC 60664-1 standard) – prevents electrical interference from low-voltage control circuits affecting detection accuracy.
    • Between high-current input terminals (e.g., CT sampling) and low-voltage control terminals: ≥2500V AC (1 minute) – ensures safety for operators and low-voltage components.

2.2 Detection Capabilities & Parameters

  • Overcurrent/Overload Detection:
    • Input signal type: AC current (via standard industrial CTs with ratio 50:5A, 100:5A, or 200:5A; compatible with most low-voltage CT specifications).
    • Detection range: 0–200A (continuous current), 0–1000A (short-term surge current).
    • Accuracy: ±3% (within 15%–100% of full scale) – meets precision needs of low-voltage systems.
    • Response time: ≤100μs (for short-circuit current exceeding 200% of rated value; fast enough to protect low-voltage IGBT modules).
  • Overvoltage/Undervoltage Detection:
    • Input signal type: AC grid voltage (direct sampling for 220V/380V systems, or via VT for 690V systems).
    • Detection range (AC): 0–800V (rms).
    • Accuracy: ±2% (within 30%–100% of full scale).
    • Configurable thresholds: Overvoltage (typically 110%–120% of rated voltage), undervoltage (typically 80%–90% of rated voltage) – set via dip switches or software.
  • Temperature Monitoring:
    • Input channels: 1 channel (for connecting NTC thermistors on low-voltage IGBT heatsinks or drive cabinets).
    • Detection range: -30°C to +120°C.
    • Accuracy: ±3°C (within -10°C to +100°C).
    • Overtemperature alarm threshold: Fixed at 85°C (or user-configurable via software) – prevents overheating of low-voltage power components.
  • Phase Loss Detection:
    • Supported signal: 3-phase AC input (for low-voltage drives or converters).
    • Detection time: ≤50ms – avoids motor burnout or converter damage caused by 3-phase imbalance.